Order Helpline 01752 692 206
Order Helpline 01752 692 206

DuPont Tyvek Metal Vapour Permeable Roofing Felt Underlay - 25m x 1.5m

Code:
D14669067

Designed to facilitate the drainage of condensation that accumulates beneath stainless steel, aluminium, copper and zinc roofs and rigid standing seam cladding, this metal roof drainage membrane protects the roof structure and thermal insulation. It is vapour permeable and ide... Read More

£308.00 Incl. VAT
Earn points

SUPER Rewards Earn points and build more across our SUPERSTORES!

Find out more
Oops! Please select from the options
Est. Delivery: 20-30 Working Days
Shipping costs displayed in basket.
We can let you know when this product is back in stock.

This product is proving to be very popular and has unfortunately sold out.

Enter your email below and we'll notify you as soon as this product is back in stock:

For delivery Tuesday, Dec 24th - order in:
days hrs mins secs
Subject to stock availability, if products on a 24 hours service are ordered alongside products NOT on a 24 hours service, this may delay your whole order.
View Transport Policy

All delivery charges are included in the final shopping basket and are dependent on the products Scottish Highlands & the Islands where additional shipping charges will apply.

Please note that not all products will incur an additional delivery charge to the Scottish Highlands & the Islands – this is based on the costs from the manufacturer, distributor or courier providing shipping on our behalf. If your delivery address is in the Scottish Highlands and Islands, a member of our helpline team will contact you prior to processing your order should an additional delivery charge apply.

While we make every effort to ensure orders are delivered by the date required, we cannot guarantee availability from the manufacturer or the manufacturer's delivery schedules.

Any variation to web delivery date given will be advised to you by email or telephone. If we are unable to make delivery because access is not possible, we reserve the right to make a failed delivery charge.

Create a wishlist

"I have used Insulation Superstore…"

Julian

Description

Designed to facilitate the drainage of condensation that accumulates beneath stainless steel, aluminium, copper and zinc roofs and rigid standing seam cladding, this metal roof drainage membrane protects the roof structure and thermal insulation. It is vapour permeable and ideal for use under standing seam metal sheet roofs over timber boarding.

DuPont Tyvek Metal comprises of a Tyvek Supro vapour-permeable membrane that is bonded to an open mesh of polypropylene strands, which are approximately 8mm deep. It can deliver adequate separation between layers, permitting movement between the metal sheet and timber boarding. Moreover, it can decrease sound transmission generated by structure-borne sounds, such as rain clatter.

Features & Benefits: DuPont Tyvek Metal Vapour Permeable Roofing Felt Underlay - 25m x 1.5m

  • 25m length x 1.5m width
  • Roll size of 37.5m²
  • Roll weight of 11.5kg
  • Mass per unit area of 350gsm
  • UV exposure: four months
  • Composite of high density polyethylene, nonwoven and open mesh spacer
  • Ideal for use under standing seam metal sheet roofs over timber boarding
  • Vapour permeable

The open mesh of the product serves as ample support and retains a clear airspace underneath the standing seam sheet, letting any condensation drain away. The membrane's vapour permeability enables water vapour defusal through and into the mesh zone from the underlying construction. For this "breathable" function to work effectively, the supporting substrate beneath DuPont Tyvek Metal should also allow for vapour to pass through. To achieve this, it is recommended to use 150mm timber boards with a 2mm gap, which has been a tried-and-tested method.

While DuPont Tyvek Metal cannot completely eliminate the possibility of condensation forming in metal roof systems, it can significantly reduce the likelihood of condensation build-up. To effectively address this issue, a comprehensive approach to roof system design should be adopted, with a particular focus on achieving vapour control and airtightness in the internal lining. For such construction, DuPont AirGuard Reflective is a compatible air and vapour control layer.

Standards & Certification

  • Certification: CE marking

Dimensions

Length 25m Width 1500mm

Details

Permeability Air Tight Roll Size 37.5m2

Questions & Answers

Question:

Can I lay this on top of my rafters then counter batter and put a old type corrugated galvanised iron roof on ?

Answer:

Sadly not - The product must be installed over open jointed timber boarding, rather than directly over rafters, we have an install guide that you may find helpful - https://www.insulationsuperstore.co.uk/user-guides-brochures/dupont-tyvek-metal-installation-guide.html

loading...

Product Enquiry Form

DuPont Tyvek Metal Vapour Permeable Roofing Felt Underlay - 25m x 1.5m

*Required Field