Order Helpline 01752 692 206 | Open today 8:00am-5:00pm
Order Helpline 01752 692 206

BodenWarme Electric Undertile Heating Cable Kit 150w with Manual Thermostat - 1m²

Code:
CABLE150MAN1M
Free UK Delivery

An excellent choice for rooms requiring minimal temperature adjustments, this BodenWärme 150-watt Electric Undertile Heating Cable Kit with a user-friendly Manual Electric Underfloor Thermostat is the ideal underfloor heating solution for heating bathrooms and irregularly shap... Read More

Create a wishlist

"thank you for the fast delivery"

Ryszard vel Marcin Wyrwa

Description

An excellent choice for rooms requiring minimal temperature adjustments, this BodenWärme 150-watt Electric Undertile Heating Cable Kit with a user-friendly Manual Electric Underfloor Thermostat is the ideal underfloor heating solution for heating bathrooms and irregularly shaped rooms with natural stone, porcelain and ceramic tiled floors.

Unlike other, more traditional methods for heating rooms, BodenWärme's 150-watt Electric Undertile Heating Cables will also reduce the risk of hot or cold spots from occurring. Designed to fit in a 45mm deep standard single gang backbox, the white Manual Electric Underfloor Thermostat also comes with your purchase. Its simple dial control that is easy to operate will allow you to control your BodenWärme heating system based on the floor temperature and is particularly suited to rooms where minimal adjustments are required.

Features & Benefits: BodenWarme Electric Undertile Heating Cable Kit 150w with Manual Thermostat - 1m²

  • Straightforward manual thermostat in white with dial control
  • Tough Fluoropolymer conducting insulation with PVC outer insulation ensures durability
  • Robust 3.6mm dual-core wire
  • Simple, single connection point keeps the increase in floor height to a minimum
  • Lifetime warranty for complete peace of mind

If installed within a well-insulated room, BodenWärme's 150w discreet heating cables can be used as a primary heat source, meaning no need for radiators, which can take up much-needed wall space and often stand out in more modern interiors.

To improve your room's energy efficiency, you can lay heat cables over underfloor heating insulation boards (6mm or 10mm thick), which will result in less time it takes to heat up and a reduction in the amount of heat loss through uninsulated floors.

How do I calculate the correct size of BodenWärme heating kit?

To calculate which kit size is right for your project, you need to first work out the area of the whole floor space by multiplying the length of the floor by the width. Once this is done, you should then subtract any fixed furniture from the area with a clearance of less than 50mm above the floor. This will eliminate the risk of causing hot spots in your room. Once you have a total area minus the subtractions, you should deduct a further 10% from your total as this will allow for the spacing between cables and around the perimeter of the room.

Kit Contents

  • 1 x BodenWärme 150w/m² underfloor heating cable
  • 1 x Manual Electric Underfloor thermostat in white
  • 1 x Floor temperature sensor with 3m cable and flexible conduit
  • 1 x Comprehensive installation manual
  • 1 x 25mm fixing tape
  • Lifetime Warranty

Standards & Certification

  • CE Certified
  • RoHS Compliant (for guaranteed safety)

Please note:

  • Cables cannot be shortened or have excess cut off at the end. Unfortunately, once the cables have been trimmed/cut, you cannot return them.
  • The maximum total size of 150w/m² BodenWärme underfloor heating cables that a single thermostat can control is 20m². Should you require to cover an area greater than 20m², the area should be divided into separate zones and controlled via multiple thermostats.
  • As with all electrical projects governed by Part P regulations, a certified electrician must undertake all mains electrical connections.
  • The heating must be protected by a 30 Amp Residual Current Device (30mA RCD), protecting against electric shock. This can be positioned within the consumer unit or via a dedicated fused spur.
  • You should also ensure that the total current of your heating system does not exceed the current capacity of the circuit it is connected to. Standard domestic ring circuits are rated at 13 Amp, and you can take an electrical feed via a single 13 Amp fused spur.

Details

Coverage
1m2
Power Supply
AC230V +/-10% 50/60Hz
Wattage Output
150w / m2
Heat Mat Warranty
Lifetime Warranty
Certification
ROHS
TUV
CE
Element Structure
Dual Core Wire
Cable Thickness
3.6mm
Cable Spacing
80mm
Cold Tail Length
3m
Conductor Insulation
Fluoropolymer
Earth Type
100% Coverage Earth Shield
Suitable For
Natural Stone
Ceramic Tiles
Porcelain Tiles
Outer Insulation
PVC

Questions & Answers

There are currently no questions for this product.

Have a question about this product?

loading...

Product Enquiry Form

BodenWarme Electric Undertile Heating Cable Kit 150w with Manual Thermostat - 1m�

*Required Field